CFSZP - SMOKEMASTER FLUID, ICI-001-786

  • MSDS: CFSZP
  • Manufacturer: SYMTROM SYSTEMS INC
  • Product Name: SMOKEMASTER FLUID, ICI-001-786
  • National Stock Number: 1365-01-367-5695
Product Identification

Product ID:SMOKEMASTER FLUID, ICI-001-786
MSDS Date:12/10/1996
FSC:1365
NIIN:01-367-5695
MSDS Number: CFSZP

Responsible Party
SYMTROM SYSTEMS INC
17-01 POLLITT DR
FAIR LAWN, NJ 07410
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 201-794-0200

Cage: 06003

Contractor
SYMTROM SYSTEMS INC
FAIR LAWN, NJ 07410 US

Telephone: 201-794-0200

Cage: 06003

Ingredients

ETHYLENE GLYCOL (SARA 313) (CERCLA)

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: <10%

OSHA PEL N/K

ACGIH TLV: 50 PPM, VAPOR, C

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ETHYLENE OXIDE (SARA 302/313) (CERCLA)

CAS: 75-21-8

RTECS: KX2450000

Fraction By Weight: TRACE

OSHA PEL 1 PPM; SEE 1910.1047

ACGIH TLV: 1 PPM, A2; 9596

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


(SUP DAT) ETHYLENE OXIDE APPEARS ON THE NAVY LIST OF

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


CONSULTATION FROM APPROPRIATE SAFETY AND HEALTH

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:MAY CAUSE SLIGHT TRANSIENT
(TEMPORARY) IRRIT. SKIN CONT:PRLNG EXPOS NOT LIKELY TO CAUSE
SIGNIFICANT IRRIT. RPTD EXPOS MAY CAUSE SLIGHT FLAKING, TENDERNESS
& SOFTENING OF SKIN. MAY CAUSE MORE SEV RESPONSE IF SKIN IS
ABRADED (SCRATCHED/CUT). SKIN ABSORPTION:FLUID MAY CAUSE SLIGHT
IRRIT AFTER PRLNG (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CONT. (A SINGLE PRLNG EXPOS IS NOT
LIKELY TO RSLT IN MATL BEING ABSORBED THRU SKIN IN HARMFUL AMTS).
INGEST:SINGLE DOSE ORAL TOX IS LOW. NO HAZS ANTIC FROM INGEST
INCIDENTAL TO INDUS EXPOS. I NHAL:A SINGLE PRLNG (HRS) INHAL EXPOS
IS NOT LIKELY TO CAUSE ADVERSE EFTS. MISTS ARE NOT LIKELY TO BE
HAZ. VAPS (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . EYES:IRRIGATE IMMEDIATELY
W/WATER FOR AT LEAST 15 MINUTES. IF IRRITATION PERSISTS, CONTACT
MD. SKIN:WASH OFF IN FLOWING WATER OR SHOWER. NOTE TO MD:NO
SPECIFIC ANTIDOTE. SUPPORTIVE CARE. TREATMENT BASED ON JUDGMENT OF
MD IN RESPONSE TO REACTIONS OF PATIENT.

Fire Fighting

Flash Point:244F,118C
Extinguishing Media:WATER FOG, ALCOHOL FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:SMALL SPILLS:COVER W/ABSORBENT MATERIAL, SOAK
UP & SWEEP INTO A DRUM. LARGE SPILLS:DIKE AROUND SPILL & PUMP INTO
SUITABLE CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:THIS PRODUCT MAY DECOMPOSE AT ELEVATED
TEMPS, GENERATING VAPORS WHICH COULD BE IRRIT. FOR USES AT ELEVATED
TEMPS, VENT OR EXHAUST IS RECOMMENDED.
Other Precautions:EXERCISE REAS CARE & CAUT. TRACE QTYS OF ETHYLENE
OXIDE (EO) MAY BE PRESENT IN THIS PROD. WHILE THESE TRACE QTYS
ACCUM IN HEADSPACE AREAS OF STOR & TRANSPORT VESSELS, THEY ARE NOT
EXPECTED TO CREATE C NDTN WHICH WILL RSLT IN EO CONCS(SUPDAT)

Exposure Controls

Respiratory Protection:WHEN AIRBORNE EXPOSURE GUIDELINES &/OR COMFORT
LEVELS MAY BE EXCEEDED, USE A NIOSH APPROVED AIR-PURIFYING
RESPIRATOR. NIOSH APPROVED ORGANIC VAPOR RESPIRATORS W/PARTICULATE
FILTERS CAN BE USED TO DECR EASE EXPOSURE.
Ventilation:GOOD GENERAL VENTILATION SHOULD BE SUFFICIENT FOR MOST
CONDITIONS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
CNDTNS(STAB):OCCURS RAPIDLY AT TEMPS APPROACHING FLASH POINT. EFTS OF
OVEREXP:AT ROOM TEMP ARE UNLIKELY DUE TO PHYSICAL PROPERTIES. OTHER
PREC:>0.5 PPM (8 HR TWA) IN BRTHG ZONE OF WORKPLACE FOR APPROP
APPLICATIONS, OSHA HAS ESTABLISHED A PEL OF 1 PPM 8 HR TWA FOR EO
(CFR PART 1910.1047 OF TITLE 29).(ING 3)

Chemical Properties

Boiling Pt:B.P. Text:379F,193C
Vapor Pres:14.33 @20C
Spec Gravity:1.0446
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS/VISCOUS LIQUID; LOW ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS.
Stability Condition to Avoid:STABLE UNDER NORMAL STOR CNDTNS. PROD
DEGRADES WHEN STORED AT ELEVATED TEMPS IN PRESENCE OF AIR.
DEGRADATION (SUPDAT)
Hazardous Decomposition Products:PROPIONALDEHYDE, CARBON MONOXIDE IN
THE PRESENCE OF LIMITED OXYGEN IN A FIRE SITUATION.

Disposal

Waste Disposal Methods:REPROCESS OR BURN IN AN APPROVED INCINERATOR
I/A/W ALL FEDERAL, STATE & LOCAL REQUIREMENTS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.